Abstract

The paper presents the compensation of harmonic, reactive power, dc voltage regulation and power factor improvement under nonlinear load condition is achieved by using Distribution Static Compensator (D-STATCOM). The synchronous reference frame control algorithm is developed for generating switching reference control signals. The dc link voltage is regulating with PI and PSO-PI controller. The attain control algorithm reference switching signals compared in hysteresis signal for better switching of D-STATCOM. The behaviour of DSTATCOM with PI and PSO-PI controller is also study and measure in terms of for DC link voltage, harmonic distortion, power factor correction and reactive power mitigation by using MATLAB/SIMULINK software.

##plugins.themes.academic_pro.article.details##

How to Cite
Reddy, S. R., Prasad, P. V., & Srinivas, G. N. (2020). Performance Comparison of DSTATCOM with PI and PSO-PI Controller under Nonlinear Load Condition. Power Research - A Journal of CPRI, 115–124. https://doi.org/10.33686/pwj.v16i2.153673

References

  1. Bose JB. Global energy scenario and impact of power electronics in 21st Century. IEEE Trans Ind Electron. 2013; 60(7):2638-51. https://doi.org/10.1109/TIE.2012.2203771
  2. Mahela OP, Shaik AG. Power quality improvement in distribution network using DSTATCOM with battery energy storage system. International Journal of Electrical Power and Energy System. 2016; 83:229-40. https://doi. org/10.1016/j.ijepes.2016.04.011
  3. Zaveri N, Chudasama A. Control strategies for harmonic mitigation and power factor correction using shunt active filter under various source voltage conditions. International Journal of Electrical Power and Energy System. 2012; 42:661-71. https://doi.org/10.1016/j.ijepes.2012.04.010
  4. Zaveri T, Bhalja BR, Zaveri N. A novel approach of reference current generation for power quality improvement in three-phase, three-wire distribution system using DSTATCOM. International Journal of Electrical Power and Energy System. 2011; 33:1702-10. https://doi.org/10.1016/j. ijepes.2011.08.011
  5. Singh B, Jayaprakash P, Kothari DP. New control approach for capacitor supported DSTATCOM in three-phase four wire distribution system under non-ideal supply voltage conditions based on synchronous reference frame theory. Int J Electrical Power and Energy Systems. 2011; 33:1109- 17. https://doi.org/10.1016/j.ijepes.2010.12.006
  6. Kannan VK, Rengarajan N. Photovoltaic based distribution static compensator for power quality improvement. Int J Electrical Power and Energy Systems. 2012; 42:686-92. https://doi.org/10.1016/j.ijepes.2012.04.061
  7. Mikkili S, Panda AK. Real-time implementation of PI and fuzzy logic controllers based shunt active, filter control strategies for power quality improvement. Int J Electrical Power and Energy Systems. 2012; 43:1114-26. https://doi. org/10.1016/j.ijepes.2012.06.045
  8. Kanjiya P, Singh B, Chandra A, Al-Haddad K. SRF Theory Revisited to control self-supported Dynamic Voltage Restorer (DVR) for Unbalanced and Nonlinear Loads. IEEE Transactions on Industry Applications, 2013; 49(5):2330- 40. https://doi.org/10.1109/TIA.2013.2261273
  9. Reddy SR, Prasad PV, Srinivas GN. Design of PI and fuzzy logic controllers for distribution static compensator. International Journal of Power Electronics and Drive System (IJPEDS). 2018; 9(2):465-77. https://doi. org/10.11591/ijpeds.v9.i2.pp465-477
  10. Reddy SR, Prasad PV, Srinivas GN. Balanced voltage sag and swell compensation by using dynamic voltage restorer. 2016 IEEE 1st International Conference on Power Electronics. Intelligent Control and Energy Systems (ICPEICES): Delhi; 2016. p. 1-6. https://doi.org/10.1109/ ICPEICES.2016.7853263
  11. Liu W, Il-Yop C, Li L, Siyu L, Cartes DA. Real-time particle swarm optimization based current harmonic cancellation. International Journal of Engineering Applications of Artificial Intelligence. 2011; 24:132-41 https://doi. org/10.1016/j.engappai.2010.08.004
  12. Gowtham G, Lakshmi Devi A. Power loss reduction and voltage profile improvement by DSTATCOM using PSO. International Journal of Engineering Research and Technology (IJERT). 2015; 4(2):553-57.
  13. Fereidouni A, Masoum MAS, Mehr TH, Moghbel M. Improving performance of shunt active power filter with hysteresis-based direct current control using particle swarm optimisation. Australian Journal of Electrical and Electronics Engineering. 2014; 11(4):357-65. https://doi. org/10.7158/E13-154.2014.11.4
  14. Parimala V, Pandian SC, Ganeshkumar D. An efficient particle swarm optimization technique for 4-leg shunt active power filter. Circuits and Systems. 2016; 7:1546-1559. https://doi.org/10.4236/cs.2016.78135
  15. Patnaik SS, Panda AK. Real-time performance analysis and comparison of various control schemes for particle swarm optimization-based shunt active power filters. International Journal of Electrical Power and Energy System. 2013 May; 52:185-97. https://doi.org/10.1016/j.ijepes.2013.03.014