Assessment of agedInsulating Oil of Transformer in Service for Ranking of Health Condition

##plugins.themes.academic_pro.article.main##

P. K. Maiti

Abstract

Power transformers are the most critical machinery in power transmission and distribution system. Failure of a transformer causes huge loss of revenue and also affects the reliability of power supply to the consumers. With the increasing population of transformers in service and their extended operating duration, extensive care is being paid on their reliability and availability. The health status of transformer is needed to be ascertained in order to avoid any possible outage and decide a suitable maintenance schedule. Insulating oil is one of the most important components of a transformer. There is a need for continuous monitoring and assessing ageing tendency of insulating oil as an essential part for estimating remaining life of a power transformer. This paper presents the concept of Ageing Index through relative scoring of various oil parameters like Acidity, Interfacial tension, Breakdown voltage, Water content and Tan delta through a scheme that combines theses results of routine oil tests. A simplified software program is used for analyzing the results of routine oil parameter testing. This paper includes a case study on several power transformers that are in continuous service with commissioning period ranging from year 1956 to 2016.

##plugins.themes.academic_pro.article.details##

How to Cite
Maiti, P. K. (2017). Assessment of agedInsulating Oil of Transformer in Service for Ranking of Health Condition. Power Research - A Journal of CPRI, 583–592. Retrieved from https://node6473.myfcloud.com/~geosocin/CPRI/index.php/pr/article/view/1023

References

  1. W. Hribernik, G. Pascoli, and K. Frölich, “An advanced model-based diagnosis system for online detection of the moisture content of power transformer insulations,” IEEEInternational Symposium Electrical Insulation 2008, vol. 2, pp. 187-191, June 2008.
  2. L. E. Lundgaard, W. Hansen, D. Linhjell and T. J. Painter, “Aging of oil-impregnated paper in power transformers,” IEEE Trans. Power Deliv., vol. 19, pp. 230-239, Jan. 2004.
  3. M. Ali, C. Eley, A. M. Emsley, R. Heywood and X. Xiao, “Measuring and understanding the ageing of kraft insulating paper in power transformers,” IEEE Electr. Insul. Magazine,vol. 12, pp. 28-34, May-June 1996.
  4. M. Wang, A. J. Vandermaar, K. D. Srivastava, “Review of Condition Assessment of Power Transformers in Service” (IEEE Electrical Insulation Magazine, Vol. 18, No. 6, 2002, pages 12-25).
  5. Z. Gao, J. McCalley, “A Transformer Health Assessment Ranking Method – Use of Model Based Scoring Expert System” (North American Power Symposium, 2009, pages 1-8).
  6. H. Gago, E. Palazuelos, J. I. Anguas, S. Quintin, “New approach of maintenance of power transformers and main accessories: off-line test vs. on-line monitoring systems” CIGRE, pages 1-24 2010.
  7. T. V. Oommen, T. A. Prevost, “Cellulose Insulation in Oil-Filled Power Transformers: Part II – Maintaining Insulation Integrity and Life” (IEEE Electrical Insulation Magazine, Vol. 22, No. 2, 2006, pages 5-14).
  8. K. Baburao, N. M. Bhangre, A. M. Wagle, A. Venkatasami, S. E Chaudhari, “The experience of DP and furan in remnant life assessment of power transformer” Condition Monitoring and Diagnosis, CMD, pages 555-558, 2008.
  9. L. Chaohui, Z. Bide, Y. Yuchun, “The Aging Diagnosis of Solid Insulation for Oil-Immersed Power Transformers and Its Remaining Life Prediction” (Asia-Pacific Power and Energy Engineering Conference (APPEEC), 2010, pages 1-3).
  10. G. J. Pukel, R. Eberhardt, H. M. Muhr, F. Baumann, W. Lick, “Large Power Transformers for Alternative Insulating Fluids”, Proceedings of the 16th International Symposium on High Voltage Engineering, Innes House, Johannesburg, Paper F-27, 2009.
  11. Siemens Alternative Insulating Liquid Transformers, Published by and copyright © 2014: Siemens AG, Energy Sector, Freyeslebenstrasse 1, 91058 Erlangen, Germany
  12. Kapila Bandara, Chandima Ekanayake, Tapan Saha and Hui Ma, “Performance of Natural Ester as a Transformer Oil in Moisture-Rich Environments” Energies 2016, 9, 258.
  13. Cigré working group A2.35: “Technical brochure 436- Experiences in service with new insulating liquids”
  14. P Macshane, et al: “Natural ester dielectric fluid development”, 2005 IEEE/PES transmission and distribution conference, Dallas, 2006.
  15. S Tenbohlen, et al: “Application of vegetable oil-based insulating fluids to hermetically sealed power transformers” Cigre Paris session, 2008, pp 7.
  16. IEC: IEC 60156 Ed. 2.0b: “Insulating liquids - Determination of the breakdown voltage at power frequency - Test method”, 1995).
  17. C. P. McShane, "Relative properties of the new combustion resistant vegetable oil based dielectric coolants," in the Records of Industry Applications Society 47th Annual conference on Petroleum and Chemical Industry, pp. 265-272, 2000, San Antonio, TX.
  18. Cigre working group. A2.35, "Experinece in Service with New Insulating Liquids", Cigre Brochure 436, 2010.
  19. IEC Std. 61099-2010, "Insulating liquids Specifications for unused synthetic organic esters for electrical purposes".
  20. V. N. Bakunin and O. P. Parenago, "Mechanism of thermo-oxidative degradation of polyol ester lubricants", Journal of Synthetic Lubrication, Vol. 9, pp. 127-143, 1992.
  21. I. Fofana, A. Bouaicha, M. Farzaneh, and J. Sabau, "Ageing Behaviour of Mineral Oil and Ester Liquids: a Comparative Study," in Annual report of IEEE conference on Electrical Insulation and Dielectric Phenomena, pp. 87-90, 26-29 Oct. 2008, Quebec, QC
  22. I. Fofana, A. Bouaicha, M. Farzaneh, J. Sabau, D. Bussieres, and E. B. Robertson, "Decay products in the liquid insulation of power transformers", in IET Electric Power Applications, Vol. 4, pp. 177-184, 2010.
  23. M. J. Heathcote, “Basic Materials”, in J and P Transformer Book - A Practical Technology of the Power Transformer (13th Edition),: Elsevier, 2007.
  24. N. J. Fox and G. W. Stachowiak, "Vegetable oil-based lubricants—A review of oxidation" in Tribology International, Vol. 40, pp. 1035-1046, 2007
  25. D. Gunstone, "The chemistry of oil and fat". Oxford: Blackwell, 2004.
  26. Lakshitha Naranpanawe, KapilaBandara, Tapan K. Saha, Chandima Ekanayake, P. K. Annamalai, “Effect of Pressboard Ageing on Power Transformer Mechanical Vibration Characteristics”, Proceedings of IEEE PES Asia-Pacific Power and Energy Engineering Conference , pp 1-5, 15-18 Nov. 2015, Brisbane, Australia.
  27. Kapila Bandara, ChandimaEkanayake, Tapan K. Saha, Hui Ma, “Investigation Of Moisture Influence On Dielectric Response Of Ester Oil Impregnated Pressboard", Proceedings of IEEE Power & Energy Society General Meeting, pp. 1-5, 26-30 July 2015, Denver, Co.
  28. A. Müller, M. Jovalekic, S. Tenbohlen, “Assessment of Oil Analysis Data for Medium Voltage Distribution Transformers”, XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 2011
  29. SonaliMayureshAkolkar, Bansidhar Eknath Kushare, “Remaining Life Assessment of Power Transformer”, Journal of Automation and Control, 2014, Vol. 2, No. 2, 45-48
  30. Chau Tran-Duy, ValérieMurin, Yves Bertrand And Michel Cordonnier, “ Chemical Indicators And Ageing Diagnosis Of Mv / Lv Distribution Transformers”, 22nd International Conference on Electricity Distribution, Stockholm, 10-13 June 2013, Paper 0407.
  31. P.K.Maiti, “Study on Estimation of Life Time of Transformer Oil in Service”, The Journal of CPRI, Vol. 8, Issue 4, December 2012, Page 339 – 343.
  32. ChilakaRanga, Ashwani Kumar Chandel and RajeevanChande, “Expert system for condition monitoring of power transformer using fuzzy logic”, Journal of Renewable and Sustainable Energy 9, 044901 (2017)
  33. N. A. Bakar and A. Abu Siada, “Fuzzy logic approach for transformer remnant life prediction and asset management decision,” IEEE Trans. Dielectr. Electr. Insul. 23(5), 3199–3208 (2016).
  34. A. E. B. Abu Elanien and M. M. M. Salama, “Calculation of a health index for oilimmersed transformers rated under 69 kV using fuzzy logic,” IEEE Trans. Dielectr. Electr. Insul. 27(4), 2029–2036 (2012).
  35. M. Arshad, S. M. Islam, and A. Khaliq, “Fuzzy Logic approach in power transformers management and decision making,” IEEE Trans. Dielectr. Electr. Insul. 21(5), 2343–2354 (2014).
  36. Y uan Li, Ming-Jie Tang, Feng-Jiao Wu, Guan-Jun Zhang, Shu-Hong Wang, Suwarno,”Aging Assessment of Power Transformer Using Multi-parameters”, International Journal on Electrical Engineering and Informatics - Volume 5, Number 1, March 2013, P 34-44.
  37. Sonali Mayuresh Akolkar, Bansidhar Eknath Kushare, “Remaining Life Assessment of Power Transformer”, Journal of Automation and Control, 2014, Vol. 2, No. 2, 45-48.
  38. ZhiGao, IEEE and James McCalley, William Meeker, “A Transformer Health Assessment Ranking Method - Use of Model Based Scoring Expert System” University Report.
  39. G. Tanasescu, O. Dragomir, L. Voinescu, B. Gorgan, P. V. Notingher, T. Suru, C. Melinte, “Assessment of Power Transformers Conditions Based on Health Index”, CIGRÉ Regional South-East European Conference, October 10th - 12th 2012, Hotel Hilton, Sibiu, Romania, (RSEEC 2012), Paper 110.