Reducing Auxiliary Power of Induced Draft Fans in Coal Fired Thermal Power Plants by Energy Audit

##plugins.themes.academic_pro.article.main##

Rajashekar P. Mandi
Udaykumar R. Yaragatti

Abstract

This paper describes the various opportunities for reducing the auxiliary power of induced draft fans in coal fired thermal power plants. The auxiliary power used by induced draft fans forms about 0.9 to 1.18 % of the total gross energy generation for 210 MW to 800 MW power plants. ID fans are the second largest (in rating) motor in a thermal power plant after Boiler Feed Pump (BFP). The detailed energy audit of auxiliary equipment in various thermal power stations, operational optimization and appropriate control system had shown ample scope for improving the energy efficiency of induced draft fans. The implementation of energy conservation measures reduce the average auxiliary power used by ID fans for 210 MW plant from average value of 1.18 % to 0.90 % of gross energy generation and the energy conservation schemes are economically attractive with a payback period of 1 to 5 years.

##plugins.themes.academic_pro.article.details##

How to Cite
Mandi, R. P., & Yaragatti, U. R. (2014). Reducing Auxiliary Power of Induced Draft Fans in Coal Fired Thermal Power Plants by Energy Audit. Power Research - A Journal of CPRI, 65–74. Retrieved from https://node6473.myfcloud.com/~geosocin/CPRI/index.php/pr/article/view/838

References

  1. R.N. Srivastava, Indian power development scenario a success story, but ahead lies the challenge, Electrical India, Vol. No. 37, Issue No.15, 15th August 1997, 15-28.
  2. Siddhartha Bhatt M. and Mandi R.P., Performance enhancement in coal fired thermal power plants, Part III: Auxiliary power, International Journal of Energy Research, No.23, 1999, 779-804.
  3. V.V. Lysko, et al., New-Generation CoalFired Steam Turbine Power Units, Thermal Engineering, Vol. 43, No. 7, 1996, 545-552.
  4. Rajashekar P. Mandi, et. al., Evaluation of auxiliary power in thermal power stations, ‘Proc. of the Ninth National Power System Conference’, Dec. 19-21, 1996 at IIT, Kanpur, 438-443
  5. Rajashekar P. Mandi, Improvement in energy efficiency of auxiliary equipment in TPS, National Symposium on Energy Conservation Measures in Generating Sector, Nov. 17-18, 2005, Bangalore.
  6. John S. Hsu, et. al., Comparison of Induction Motor Field Efficiency Evaluation Methods, IEEE transactions on industry applications, Vol. 34, No. 1, January/February, 1998, 117-125
  7. C. L. Becnel et al., Determining motor efficiency by field testing, IEEE Transactions on Industrial Applications, Vol. IA-23, May/June 1987, 440–443.
  8. B.L. Theraja, A Text book of Electrical Technology, (Niraja Construction & Development Co (P) ltd., New Delhi, 1983) [9] M.G. Say, The performance and design of alternating current machines (CBS Publishers & Distributors, Delhi, 1983).
  9. E l-Wakil M.M.,Power plant TechnologyInternational (McGraw-Hill Book Company, Singapore, 1984).
  10. CPRI, 2007, Instrumented & Diagnostic Energy audit at Trombay Thermal Power Station, Tata Power Co. Ltd., Mumbai, Report No: CPRI/ECDD/EA/23/07.
  11. CPRI, 2002, Instrumented & Diagnostic Energy audit at Firoz Gandhi Unchahar Thermal Power Project, Unchahar, Report No: ERC/PS/02/2002.
  12. H iroaki Yamada, et. al., High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd. Hitachi Ltd.
  13. CPRI, 2002, Instrumented & Diagnostic Energy audit at Guru Nanak Dev Thermal Power Station, Bhatinda, Report No: ERC/ PS/03/2002.
  14. G.E. Weber and S.J. Gronwold, Furnace air leakage modeling, ComEd, Fossil Division, 1411 Opus PL.-suite 250, Downers Grove, II. 60515.