Abstract

The analysis of small-signal stability of conventional power systems is well established, but for inverter based microgrids there is a need to establish how circuit and control features gave rise to particular oscillatory modes and which of these have poor damping. This paper develops the modeling and stability analysis of autonomous operation of inverter based microgrids. Each sub-module is modeled in state-space form and all are combined together on a common reference frame. The model captures the detail of the control loops of the inverter but not the switching action. Some inverter modes are found at relatively high frequency and so a full dynamic model of the network (rather than an algebraic impedance model) is used. The complete models linearized around an operating point and the resulting system matrix is used to derive the eigenvalues. The eigenvalues (termed “modes”) indicate the frequency and damping of oscillatory components in the transient response. A sensitivity analysis is also presented which helps identifying the origin of each of the modes and identifies possible feedback signals for design of controllers to improve the system stability. With experience it is possible to simplify the model (reduce the order) if particular modes are not of interest as is the case with synchronous machine models. Transient stability results have been obtained from a microgrid of three 10-kVA inverters.

##plugins.themes.academic_pro.article.details##

How to Cite
Jyothsna, T. R., Ramya Sree, B., Ramya, V., & Deshpande, R. A. (2014). Steady State and transient performance of an inverter based microgrid. Power Research - A Journal of CPRI, 785–798. Retrieved from https://node6473.myfcloud.com/~geosocin/CPRI/index.php/pr/article/view/779

References

  1. R H Lasseter, ”Microgrids,” in Proc. Power Eng. Soc. Winter Meeting Jan 2002, vol.1, pp. 305-308.
  2. A Arulapalam , M Barnes, A Engler, A Goodwin, and N Jenkins, “Control of power electronic interfaces in distributed generation microgrids,” IntJ. Electron., vol. 91,no. 9, pp. 503-523, Sep. 2004.
  3. R Lassetter, “Integration of Distributed Energy Resources: The CERTS Microgrid Concept,” CERTRep., Apr. 2002.
  4. M S Illindla, P Piagi, H Zhang, G Venkataramanam, and R H Lasseter, “Hardware Development of a LaboratoryScale Microgrid Phase 2:Operation and Control of a Two-Inverter Microgrid,” Nat. Renewable Energy Rep.,Mar. 2004.
  5. Y Li, D M Vilathgamuwa, and P C Loh, “Design, analysis and real-time testing of A controller for multibus microgrid system,’ IEEE Trans. Power Electron., vol. 19, no. 5, pp. 1195-1204, Sep. 2004.
  6. E A A Coelho, P Cortizo, and P F D Gracia, “Small signal stability for parallelconnected inverters in stand-alone ac supply systems,” IEEE Trans. Ind. Appl., vol 38, no. 2, pp. 533-542, Mar./Apr. 2002.
  7. J M Guerrero, L G V Na, M Castilla, and J Miret,”A wireless controller to enhance Dynamic performance of parallel inverters in distributed generation systems,”IEEE Trans. Power Electron., vol. 19,no. 5, pp. 1205-1213, Sep. 2004.
  8. A L Dimeas and N D Hatziargyriou, “Operation of a multiagent system for microgrid Control,” IEEE Trans. Power Syst., vol. 20, no. 3, pp. 1447-1455, Aug. 2005.
  9. M Prodanovic’, T Green, and H Mansir,” A survey of control methods for Parallel three-phase inverters connection,”Proc. Inst. Elect. Eng., no. 475, pp. 472-477, Sep. 2000.
  10. M C Chandorker, D M Divan, and A Rambabu, “Control of parallel connected inverters in stand-alone ac supply systems,” IEEE Trans. Ind. Appl., vol. 29, no. 1, pp. 136-143, Jan./Feb. 1993.
  11. J M Undrill,” Dynamic stability calculations for an arbitrary number of interconnected synchronous machines, “IEEE Trans. Power Apparat. Syst., vol PAS-87, no. 3, pp. 835845, Mar. 1968.
  12. M N Marwali, J Jung, and A Keyhani,” Control of distributed generation systemspart 11: load sharing control,” IEEE Trans Power Electron., vol. 19, no. 6, pp. 15511561, Nov. 2004.
  13. M Prodanovic’,” Power Quality and Control Aspects of Parrllel Connected Inverters in Distributed Generation,” Ph. D. dissertation, Imperial College, Univ. London, Uk, 2004.
  14. M N Marwali, J Jung, and A Keyhani,” Control of distributed generation systemspart1: voltages and current control,” IEEE Trans Power Electron., vol. 19,no. 6, pp. 1541-1550, Nov. 2004.
  15. P Kundar, POWER SYSTEM STABILITY and CONTROL. New York: Mc Graw-Hill, 1994.
  16. C A Hernandez-Aramburo, T C Green, and N. Mugniot, “Fuel consumption minimization of a microgrid,” IEEE Trans. Ind. Appl, vol. 41, no. 3, pp. 673-681, May/ Jun. 2005.
  17. A Tuladhar, H Jin, T Unger, and K Mauch, “Control of parallel inverters in distributed ac power systems with considerations of line impedance effect,” IEEE Trans. Ind. Appl, power vol. 36, no. 1, pp. 131-138, Jan./Feb. 2000.
  18. A Engler, “Applicability of droops in low voltage grids,” Int. J. Distrib. Res., vol. 1, no. 1, pp. 3-15, Sep. 2004

Most read articles by the same author(s)