Enhancing Energy Efficiency of Auxiliary Power in a Coal-Fired Thermal Power Plant

##plugins.themes.academic_pro.article.main##

Rajashekar P. Mandi
Udaykumar R. Yaragatti

Abstract

This paper describes the auxiliary power consumption in Indian coal-fired thermal power plants. The factors influencing the auxiliary power are discussed in detail increase in auxiliary power due to lower plant load factor causes for lower PLF are enumerated. The effect of poor coal quality on auxiliary power is discussed. The effect of operational optimization, adoption of new energy efficient technologies, design deficiencies, etc., is discussed in detail along with remedial measures to reduce the auxiliary power. The energy conservation measures reduce the auxiliary power of 210 MW power plant from 11.59% to 8.50% with a payback period of 1-5 years.

##plugins.themes.academic_pro.article.details##

How to Cite
Mandi, R. P., & Yaragatti, U. R. (2011). Enhancing Energy Efficiency of Auxiliary Power in a Coal-Fired Thermal Power Plant. Power Research - A Journal of CPRI, 89–100. Retrieved from https://node6473.myfcloud.com/~geosocin/CPRI/index.php/pr/article/view/676

References

  1. CEA, 2008, Performance Review of Thermal Power Stations 20062007, http//:www.cea.nic.in.
  2. Siddhartha Bhatt M and Mandi R P. "Performance enhancement in coal fired thermal power plants, Part III: Auxiliary power", International Journal of Energy Research, No. 23, pp. 779-804, 1996.
  3. Lysko V V et al. "New-generation coal fired steam turbine power units", Thermal Engineering, Vol. 43, No. 7, pp. 545-552, 1996.
  4. Joskow, Paul L. et al. "The performance of coal-burning electric generating units in the United States: 1960-1980", Journal of Applied Econometrics, Vol. 2, No. 2, pp. 85-109, 1987.
  5. CPRI, 2008, Instrumented and Diagnostic Energy audit at 5 ´ 200 MW plants at Orba TPS, UPRVUNL, Lucknow, Report No: CPRI/ECDD/EA/38/08.
  6. ICRA, 2003, "Revised report to the Power Finance Corporation of Gujarat Power Sector", ICRA Ltd., 26, Kasturba Gandhi Marg, New Delhi-110001.
  7. MECON Ltd., "Report on achievable heat rate and auxiliary power consumption of thermal power stations of MSPGCL", MECON Ltd., Ranchi-834002, August 2007.
  8. RTPS, 2008, "Generation performance of units", http//"www.karnatakapower.com
  9. DVC, "Performance parameters of TPP of DVC for Last Five Years", 2005, http//:www.dvcindia.org.
  10. Zhengyu Huang Edwards R M. "Power generation efficiency improvement through auxiliary system modification", Energy Conversion, IEEE, Transactions, Vol. 18, No. 4, pp. 525-529, November 2003.
  11. Hiroaki Yamada et al. "High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd"., Hitachi Ltd.
  12. Chris Harley, Conforma Clad inc. K. Scott Trunkett, Conforma Clad Inc. "Improving Plant Performance with Advanced Wear Protection Technologies", Coal-Ge, August 7, 2003.
  13. Weber G E and Gronwold S J, Furnace air leakage modeling, ComEd, Fossil Division, 1411 Opus PL.-suite 250, Downers Grove, II. 60515.
  14. Jonathan L. Gomez, "Modeling of air leakages on a Tri-sector Air heater", Public Service Indiana, 1987.
  15. Rajashekar P Mandi, Hegde R K and Sinha S N. "Performance Enhancement of Cooling Towers in Thermal Power Plants through Energy Conservation", published at "International conference on POWERTECH 2005" at St. Petersburg, Russia, Organized by IEEE, Power Engineering Society, 2730, June 2005, Paper No. #461.
  16. Ananth P. Chikkatur and Ambuj D. Sagar. "Cleaner power in India: towards a clean-coaltechnology roadmap", Energy Technology Innovation Policy, John F Kennedy School of Government, Harward University, Discussion pp. 2006-2007, December 2007.

Most read articles by the same author(s)

<< < 1 2